Repositioning of the humeral tuberosities can be guided by pectoralis major insertion

JOURNAL TITLE: Strategies in Trauma and Limb Reconstruction

Author
1. Alec Cikes
2. Fanny Canet
3. Étienne Trudeau-Rivest
4. Dominique M. Rouleau
5. Jonah Hébert-Davies
ISSN
1828-8936
DOI
10.1007/s11751-014-0205-z
Volume
9
Issue
3
Publishing Year
2014
Pages
5
Author Affiliations
    1. Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Gouin Ouest, Local C-2095, Montreal, QC H4J 1C5, Canada; Synergie-Medical Center, Rue du Grand-Pré 2B, 1007 Lausanne, Switzerland
    1. Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Gouin Ouest, Local C-2095, Montreal, QC H4J 1C5, Canada; University of Montreal, 2900 Boulevard Edouard-Montpetit, Montreal, QC H3T 1J4, Canada
    1. Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Gouin Ouest, Local C-2095, Montreal, QC H4J 1C5, Canada
    1. Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Gouin Ouest, Local C-2095, Montreal, QC H4J 1C5, Canada; University of Montreal, 2900 Boulevard Edouard-Montpetit, Montreal, QC H3T 1J4, Canada
    1. Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Gouin Ouest, Local C-2095, Montreal, QC H4J 1C5, Canada; University of Montreal, 2900 Boulevard Edouard-Montpetit, Montreal, QC H3T 1J4, Canada
  • Article keywords
    Shoulder, Pectoralis major, Bicipital groove, MRI, Tuberosity, Proximal humerus fracture

    Abstract

    In complex proximal humerus fractures, positioning of the tuberosities can be a challenge. This study demonstrates the constant angle between the pectoralis major (PM) and the medial lip of the bicipital groove (BG) on the horizontal axial plane. This angle can be used to determine the rotation, as well as the positioning of the tuberosities, when planning a hemiarthroplasty or a reconstruction. Thirty-one shoulder MRIs were reviewed by three independent observers. The measurements were taken by superposing the axial cut of the proximal humerus, at the level of the distal bicipital groove, and the cut at the top of the PM insertion. By aligning the centers of rotation, we could determine the arcs of rotation between the insertion of the PM and the lips of the medial and lateral bicipital groove (MBG and LBG). Both angles were compared in terms of reliability, reproducibility, and precision. The mean PM–MBG angle was 3.7° [standard deviation (SD) 14.7°] and 27.4° (SD 14.4°) for the PM–LBG angle. We obtained good and very good intra-class correlation coefficient (ICC) results for inter- (0.675) and intra-observer (0.793) reliabilities on the medial angle, plus excellent results for the lateral angle (inter-observers 0.962 and intra-observer 0.895). This study demonstrates that the repositioning of humeral tuberosities can be guided by pectoralis major insertion. This will help achieve proper positioning of the metaphysis in relation to the diaphysis during surgery for complex proximal humerus fractures.

    © 2019 Jaypee Brothers Medical Publishers (P) LTD.   |   All Rights Reserved