Comparison between Serum Calcium Levels Measured Using Direct Ion-selective Electrodes and Photometric Method in Automated Analyzers

JOURNAL TITLE: Indian Journal of Medical Biochemistry

Author
1. Parul Arora
2. Sudip K Datta
3. Ashish D Upadhyay
ISSN
0972-1207
DOI
10.5005/jp-journals-10054-0128
Volume
24
Issue
1
Publishing Year
2020
Pages
4
Author Affiliations
    1. University College of Medical Sciences and Guru Teg Bahadur Hospital, Delhi, India
    2. Malhotra Test Tube Baby Center, Agra, Uttar Pradesh, India
    3. Rainbow Hospitals, Agra, Uttar Pradesh, India
    4. Postgraduate Institute of Medical Education and Research, Chandigarh, India
    5. Nova IVF Fertility, Ahmedabad, Gujarat, India
    1. Department of Laboratory Medicine, All India Institute of Medical Sciences, New Delhi, India
    1. Department of Biostatistics, All India Institute of Medical Sciences, New Delhi, India
  • Article keywords

    Abstract

    Introduction: Serum calcium is measured by photometric methods or ion-selective electrodes (ISEs). The ISEs measure free ionized calcium (FCa), which is not bound to proteins like albumin and is corrected using algorithms to calculate the total calcium, TCa (TCa_calc). The TCa obtained by photometry (TCa_meas) requires correction for albumin by several formulae to obtain the corrected Ca (TCa_corr). Aims and objectives: In this study, we aim to find the agreement between TCa levels calculated from direct ISE results (TCa_calc) and TCa levels obtained by spectrophotometric methods after correction using formulae given in the literature (TCa_corr) at different levels of serum albumin. Materials and methods: In this study, 332 serum samples were analyzed for TCa and albumin on Roche Modular P800 and FCa by direct ISE on XI-921 (Caretium) and converted to TCa_calc. The results of TCa_calc and TCa_corr were compared using paired t test. Results: Significant difference was observed between TCa_calc (2.45 ± 0.34 mmol/L) and TCa_meas (2.07 ± 0.27 mmol/L). The TCa_meas was corrected for albumin using several commonly used formulae. However, significant differences still existed between TCa_calc and TCa_corr. The cases were further subdivided into three groups on the basis of serum albumin; however, significant differences were observed between TCa_calc and TCa_corr values in all subgroups. Conclusion: Caution should be exercised while interchangeable usage and interpretation of serum calcium levels from direct ISE vis-à-vis photometric methods. Clinical significance: With the infiltration of point-of-care devices in casualties and intensive care units, awareness needs to be created among clinicians regarding the potential misinterpretations of the tests involved. Regulatory guidelines to the same effect may also be considered.