Intrastromal Corneal Ring Segments Implantation in Patients with Mild Keratoconus

JOURNAL TITLE: International Journal of Keratoconus and Ectatic Corneal Diseases

Author
1. Pablo F Rodrigues
2. Wagner G Dias
ISSN
2277-3800
DOI
10.5005/jp-journals-10025-1091
Volume
3
Issue
3
Publishing Year
2014
Pages
5
Author Affiliations
    1. Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, SP, Brazil
    1. Sector of Cornea and Cataract Hilton Rocha Institute, Belo Horizonte, MG, Brazil
  • Article keywords

    Abstract

    Purpose

    The purpose of this study is to evaluate the topographic, topometric and visual changes after implantation of Ferrara intrastromal corneal ring segments (ICRS) in grades I and II keratoconus patients.

    Materials and methods

    The chart records of 50 consecutively operated keratoconus patients were reviewed. The patients were operated on by the same surgeon, with the manual technique. All patients were preoperatively and postoperatively evaluated with the Pentacam (OCULUS Optikgeräte, Wetzlar, Germany). The studied parameters were: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, corneal asphericity and corneal volume.

    Results

    Fifty eyes of 42 patients (26 males and 16 females) were analyzed. The mean preoperative UDVA was 0.91 ranging from LogMAR 0.10 to 1.30. The mean postoperative CDVA was 0.19 ranging from 0.00 to 0.54 LogMAR. The postoperative CDVA was equal or better than 0.18 in 37 cases (74%). The mean K1 decreased from 45.80D (±2.52) preoperatively to 44.27D (± 2.10) postoperatively and the mean K2 value, from 49.06D (± 2.09) to 46.22D (±1.89). The mean asphericity increased from −0.71 preoperatively to −0.29 postoperatively. The average preoperative corneal volume was 56.89 ± 3.11 mm3 while the average postoperative corneal volume was 57.64 ± 3.05 mm3.

    Conclusion

    The study supports the early indication of implantation of Ferrara ICRS in mild to moderate keratoconus cases in order to achieve good visual, keratometric and ashpericity outcomes.

    How to cite this article

    Rodrigues PF, Ferrara G, Ferrara P, Dias WG, Torquetti L. Intrastromal Corneal Ring Segments Implantation in Patients with Mild Keratoconus. Int J Kerat Ect Cor Dis 2014;3(3):122-126.